Safety
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

△
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present

□
Double insulation
-
Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter.
-
Make sure any covers or battery doors are properly closed and ured.
-
Always remove the test leads before replacing the battery or fuses.
-
Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair any damage before use.
-
Do not exceed the maximum rated input limits.
-
Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard.
-
Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests.
-
Remove the battery from the meter if the meter is to be stored for long periods.
-
To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC.
| Input Limits | |
| Function | Maximum Input |
| VDC, VAC | 600V AC/600V AC |
| Resistance, Diode, Continuity | 500V DC/AC |
| mA DC | 200mA DC |
| 10A DC | 10A DC (15 seconds max. every 15 min.) |
| Frequency | 250V DC/AC |
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.
User's Manual
EXTECH INSTRUMENTS
MiniTec™ Series Model MN36 Auto-Ranging Mini MultiMeter

3999
Introduction
Congratulations on your purchase of Extech's MN36 Auto-Ranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Temperature, Diode Test and Continuity. Proper use and care of this meter will provide many years of reliable service.
Specifications
| Accuracy | Stated at $ 73°F \pm 10°F $ ( $ 23°C \pm 5°C $) and less than 70% RH | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Diode Test | Test current of 0.6mA maximum, open circuit voltage 1.5V DC typical | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Continuity Check | Audible signal will sound if the resistance is less than approximately
Specifications