W11212322
- IM SOLENOID GROUNDED THROUGH MOUNTING. 2. EVAP COVER GROUNDED HEAT SHIELD.
WIRING DIAGRAM
WIRE COLOR CODE WH/GN = WHITE/GREEN TRACER OR/BK = ORANGE/BLACK TRACER YL/RD = YELLOW/RED TRACER BU/BK = BLUE/BLACK TRACER WH/BU = WHITE/BLUE TRACER BK/YL = BLACK/YELLOW TRACER WH/RD = WHITE/RED TRACER GN/YL = GREEN/YELLOW TRACER YL/BK = YELLOW/BLACK TRACER PK/BK = PINK/BLACK TRACER
WIRE COLOR CODE BR/WH = BROWN/WHITE TRACER OR/BU = ORANGE/BLUE TRACER RD/WH = RED/WHITE TRACER LB/BK = LIGHT BLUE/BLACK TRACER TN/WH = TAN/WHITE TRACER TN/BK = TAN/BLACK TRACER RD/YL = RED/YELLOW TRACER V/WH = VIOLET/WHITE TRACER BL/YL = BLUE/YELLOW TRACER YL/BU = YELLOW/BLUE TRACER
WIRE COLOR CODE BU = BLUE BK = BLACK RD = RED WH = WHITE YL = YELLOW OR = ORANGE BR = BROWN GY = GRAY PK = PINK V = VIOLET TN = TAN
MANUFACTURED UNDER ONE OR OF THE FOLLOWING UNITED STATES PATENTS 3,960,631 4,659,157 4,765,696 4,908,544 5,011,101 4,084,725 4,665,708 4,767,896 4,911,508 5,033,182 4,090,641 4,694,553 4,768,353 4,914,928 5,033,273 4,102,660 4,706,169 4,776,178 4,920,758 5,042,398 4,327,557 4,707,401 4,787,216 4,924,680 5,044,704 4,330,310 4,709,556 4,799,362 4,934,541 5,050,777 4,640,432 4,715,512 4,800,935 4,936,641 5,070,708 4,649,712 4,728,759 4,801,181 4,944,566 5,077,985 4,649,717 4,745,656 4,833,894 4,958,890 D309,461 4,649,718 4,745,775 4,862,577 4,996,848
| VOLTAGE TEST POINTS THESEUS | ||||||
|---|---|---|---|---|---|---|
| MAIN CONTROL (ACU) | CONNECTOR | FROM | COLOR | TO | COLOR | SPECIFICATIONS |
| P1 | P1-1 | BK | P1-2 | WH | 120VAC Input Constant from Power Cord. | |
| P1-2 | WH | P1-4 | RD | 120VAC Output to Compressor/Condenser Fan When Cooling | ||
| P2 | P2-1 | YL/RD | P1-1 | BK | 120VAC input FC Light switch feedback | |
| P2-4 | YL | P1-1 | BK | 120VAC input FC Light switch feedback | ||
| P2-6 | RD/WH | P1-2 | WH | 120VAC Output to Evap Fan when cooling | ||
| P2-7 | BR | P1-2 | WH | 120VAC Output Defrost Heater when defrosting. | ||
| P3 | P3-4 | V | P1-2 | WH | 120VAC Output to Water Valve when Water dispensing | |
| P3-5 | LB | P1-1 | BK | 120VAC Input FC Door Switch | ||
| P3-6 | GY/OR | P1-2 | WH | 120VAC Output to Cube Solenoid when dispensing Cube | ||
| P3-8 | BU | P1-2 | WH | 120VAC Output to Auger Motor when dispensing ice | ||
| P4 | P4-1 | OR | P4-4 | LB | 12.7 VDC Output to User Interface | |
| P4-3 GY | DATA COMMUNICATION | |||||
| P5 | P5-1 | GY | P5-2 | GY | 5 VDC INPUT RC THERMISTOR | |
| P5-3 | TN | P5-4 | TN | 5 VDC INPUT FC THERMISTOR | ||
| P8 | P8-1 | PK | P8-2 | PK | 5 VDC INPUT DEFROST THERMISTOR | |
| P8-7 | V | P8-8 | RD | 12.7 VDC Output to Dispenser LED | ||
| P70 | P70-7 BU | 12 VDC Pulse Damper Stepper Motor coil A + | ||||
| P70-8 WH | 12 VDC Pulse Damper Stepper Motor coil A - | |||||
| P11 | P11-1 YL | 12 VDC Pulse Damper Stepper Motor coil B + | ||||
| P11-2 RD | 12 VDC Pulse Damper Stepper Motor coil B - | |||||
| P11-3 | BR | P11-4 | BR | 12 VDC Output to damper Heater | ||
| VOLTAGE TEST POINTS MINOTAUR | ||||||
| HMI | CONNECTOR | FROM | COLOR | TO | COLOR | SPECIFICATIONS |
| J1 | J1-1 | LB | J1-4 | OR | 12.7 VDC Output to User Interface | |
| J1-2 GY | DATA COMMUNICATION |
Table Caption: This table details voltage test points for the THESEUS and MINOTAUR systems, specifying connector pins, wire colors, and voltage specifications for various electrical components. It outlines both AC and DC voltage inputs and outputs to control units, sensors, motors, and user interfaces.
SERVICE SHEET
SERVICE INFORMATION ( W11212314 A )
- COMPRESSOR SUCTION AND PROCESS STUBS MAY NOT BE INTERCHANGED.
- REFRIGERANT CHARGE MUST BE APPLIED TO HIGH SIDE ONLY.
- ICE MAKER AND WATER VALVE NOT ORIGINAL EQUIPTMENT ON ALL MODELS.
- NOTE: ICE MAKER CYCLE MUST BE INITIATED ELECTRICALLY. DO NOT TRY TO MANUALLY START CYCLE.
- PART NUMBER CAN BE FOUND ON THE COMPONENT.
| SERVICEABLE ELECTRICAL PARTS MATRIX | |||||
|---|---|---|---|---|---|
| SERVICEABLE PARTS | EGX60HLC | WATTAGE 115 - 127V AC | EM3Y60HLP | WATTAGE 115 - 127V AC | RESISTANCE ( GLYPH<1>^GLYPH<2> |
| COMPRESSOR | W11045354 | 102 | W11181053 | 109 | |
| RUN WINDINGS | - | - | 1-5 | ||
| START DEVICE, OVERLOAD | See Note 5 | See Note 5 | |||
| RUN CAPACITOR (IF EQUIPPED) | See Note 5 | See Note 5 | |||
| ELECTRIC AIR BAFFLE ASSY | See Note 5 | 12V DC | See Note 5 | 12V DC | |
| THERMISTOR | See Note 5 | See Note 5 | 2.7KGLYPH<1>^GLYPH<2> AT 25GLYPH<1>$GLYPH<2>C | ||
| USER INTERFACE CONTROL | See Note 5 | See Note 5 | |||
| MAIN CONTROL | See Note 5 | See Note 5 | |||
| DEFROST HEATER | See Note 5 | 550-650 | See Note 5 | 550-650 | |
| EVAPORATOR FAN MOTOR | See Note 5 | 2-9 | See Note 5 | 2-9 | |
| CONDENSER FAN MOTOR | See Note 5 | 3-12 | See Note 5 | 3-12 |
Table Caption: This matrix lists serviceable electrical parts for two models, EGX60HLC and EM3Y60HLP, detailing their corresponding part numbers, wattage or voltage specifications, and resistance values where applicable.
COMPRESSOR OPTIONS - REFER TO APPLICABLE DESIGN ( OIL COOLER NOT PRESENT ON ALL COMPRESSORS )
- Normal operating conditions are viewed when the air and temperature controls are at mid-sitting, freezer section 0 to -5GLYPH<1>$GLYPH<2>F and unit is cycling.
NOTE: Watt and pressure readings will vary and are influenced by the existing condition of the appliance, such as iced-up evaporator, condition of condenser, defrost cycle, pull-down time and customer use.
SERVICE SHEET W11125079 REV B
SERVICE KEY ASSIGNMENTS
CRUSH
DURING THE FIRST FIVE MINUTES AFTER A POWER ON, PUT THE SETTING TEMPERATURE AT MINIMUM POSITION FOR BOTH RC AND FC. AFTERWARDS HOLD "FREEZER TEMP" AND "ICE TYPE" KEYS FOR 3 SECONDS TO ENTER SERVICE MODE. AFTER ENTERING SERVICE MODE, ALL LEDS WILL TURN ON TO VERIFY ALL LED CAN TURN ON.
TO PROCEED TO SERVICE STEPS, USER SHALL PRESS ALL 5 KEYS INDIVIDUALLY FROM LEFT TO RIGHT TO TURN OFF ALL LEDS AND VALIDATE TOUCH FUNCTION.
| KEYS | DESCRIPTION |
|---|---|
| SW2=LIGHT KEY | INCREMENT KEY: ADVANCE TO NEXT STEP |
| SW4=LOCK KEY | DECREMENT KEY: GO BACK TO PREVIOUS STEP |
| SE5=RC TEMP KEY | CHANGE SETTING KEY: TURN ON/OFF LOAD, PAUSE/RUN SPECIFIC TEST |
Table Caption: This table outlines the functions of three keys: SW2 increments through steps, SW4 decrements through steps, and SE5 changes settings such as turning loads on/off or pausing/running specific tests.
NOTE: FOR SMOOTH OPERATION OF USER INTERFACE KEY ACTIVATION, WAIT AT LEAST 1 SECOND BETWEEN EACH PRESS, TO LET THE SYSTEM TOGGLE BETWEEN SERVICE STEPS.
NOTE: FOR IDI MODEL WITH TWIST TRAY ICE MAKER, UPON ENTRY INTO SERVICE, ICE MAKER IS ENABLED AND A HOMING OPERATION IS PERFORMED, THIS IS TO AVOID OF ANY OTHER LOAD INTERFERENCE WHEN SANKYO IM IS PERFORMING THE HOMING OPERATION. THE LEDS ON THE FREEZER TEMP SECTION WILL SHOW THE STEP NUMBER WHILE