SERVICE TIPS

AMES/AES/ROYALE/ELITE REFRIGERATORS

Models

SILHOUETTEDOMETICDOMETICDOMETIC
AMES/AESAMES/AESROYALEELITE
S1521RM2607RM3662RM4872
S1531RM2611RM3663RM4873
S1621RM2807RM3862
S1631RM2811RM3863
S1821RM3607
S1831RM3807

Refrigerator Start-Up Information

The new Dometic Refrigerator has been designed to provide more cooling power than ever before — surpassing all agency requirements and customer expectations. When starting this refrigerator for the very first time, the cooling cycle may require up to four hours of running time before the cooling unit is fully operational.

REVISION:

Form No. 3309479.008 10/04

(Replaces OS1662)

©2004 Dometic Corporation

LaGrange, IN 46761

THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2811, RM3607, RM3807, RM3662, RM3663, RM3862, RM3863, RM4872 and RM4873 REFRIGERATORS.

SYMPTOM

1.No operation - no panel lightsOperation DC Volts Fuse Wiring Upper Circuit Board Lower Circuit Board
2.No operation - has panel lightsOperation DC Volts Thermistor Fuses Upper Circuit board Wiring Lower Circuit Board
3.No AC operation - operates on other mode(s)Operation AC Volts Fuse Heating Element Upper Circuit Board Wiring Lower Circuit Board
4.No DC operation - operates on other mode(s)Operation DC Volts Fuse Heating Element Upper Circuit Board Wiring Lower Circuit Board
5.No gas operation - operates on other mode(s)Operation LP Gas Manual Gas Valve Igniter High Voltage Cable Electrode Solenoid Upper Circuit Board Wiring Lower Circuit Board
6.Insufficient cooling on all mode(s).Ventilation Leveling Ambient Temperature Air Leaks Thermistor Cooling Unit Thermistor Adjuster

SYMPTOM

  1. Insufficient cooling on AC-cools properly on other mode(s)

  2. Insufficient cooling on DC - cools properly on other mode(s)

  3. Insufficient cooling on gas - cools properly on other mode(s)

  4. Freezes

  5. Changes preset mode

  6. Check light on

CAUSE

AC Volts

Heating Element

Lower Circuit Board

  1. Interior light on when door is closed

DC Volts

Heating Element

Wiring

Lower Circuit Board

Thermistor

Thermistor Adjuster

Lower Circuit Board

Upper Circuit Board

LP gas

Orifice

Flue Baffle

Flue Tube

Flue Cap (if equipped)

Burner

Lower Circuit Board

Operation

DC Volts

Wiring

Upper Circuit Board

Lower Circuit Board

  1. Rapid formation of frost

  2. Water on frame

DC Volts

Wiring

LP Gas

Manual Gas Valve

Solenoid

Orifice

Burner

Lower Circuit Board

Thermocouple

Wiring

Door Switch

Door Position

Food Storage

Interior Liner to Frame

High Humidity

Air Leaks

Interior Liner to Frame

High Humidity

Air Leaks

Climate Control Heater

ICE MAKER SECTION

SYMPTOM

  1. Ice Maker fails to start.

  2. Ice Maker won't make ice.

  3. Keeps making ice and won't shut off.

  4. Not making enough ice.

  5. Too much water is coming out.

  6. Ejector blade frozen into ice cubes.

  7. Unit is hooked-up no water comes in.

  8. Ice maker is running but won't make cubes.

  9. Ice maker will not make ice.

CAUSE

Operation

Arm in Up Position

AC Voltage

Water Valve

Ice Maker Cycle

Blades Frozen in Ice

AC Voltage

Water Valve

Ice Maker Cycle

Shut-off arm

Operation

Mold Thermostat

Cube Size

Ice Maker Cycle

Water Fill Adjustment

Water Valve

Water Fill Adjustment

Water Valve

Water

Water Valve

Water

Shut-Off Arm

Mold Thermostat

Hold Switch

Ice Ejector

Mold Heater

Timing Motor

AMES REFRIGERATOR OPERATION

2-WAY DISPLAY PANEL

Image

ON 1 OFF AC 2 GAS CHECK COLD 1 2 3 4 5 COLDEST

3-WAY DISPLAY PANEL

Image

ON DC AUTO CHECK COLD 1 2 3 4 5 COLDEST OFF AC GAS B C E F

MODELS INCLUDE: S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2811

AUTO MODE

When operating in the AUTO mode, the AUTO mode indicator lamp (D) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again, the control will switch back to AC regardless of the status of GAS operation.

GAS MODE

When operating in the GAS mode, the AUTO mode indicator lamp (D) will not be illuminated. This mode provides LP gas operation only. The control system will activate the ignition system and will attempt to light the burner for a period of approximately 45 seconds. If unsuccessful, the CHECK indicator lamp (E) will illuminate and the GAS mode indicator lamp (C) will turn off.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. The control system will attempt a new 45 second ignition sequence. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff