Salta al contenuto principale

W10341189

2 pagine · 311.90 KB · PDF

FOR SERVICE TECHNICIAN'S USE ONLY

Tech Sheet

WARNING

Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

Do not Discard

DANGER

Electrical Shock Hazard

Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before servicing. Failure to follow these instructions can result in death or electrical shock.

Voltage Measurement Safety Information

When performing live voltage measurements, you must do the following:

GLYPH<0> Verify the controls are in the off position so that the appliance does not start when energized. GLYPH<0> Allow enough space to perform the voltage measurements without obstructions. GLYPH<0> Keep other people a safe distance away from the appliance to prevent potential injury. GLYPH<0> Always use the proper testing equipment. GLYPH<0> After voltage measurements, always disconnect power before servicing.

No-Load Performance, Controls in Normal Position
Kw/24 hr ±0.4Percent Run Time ±10%Cycles/24 hr ±10%Refrigerator Compartment Average Food Temperature ±4°FFreezer Compartment Average Food Temperature ±4°FIceMaker Compartment Average Temperature ±5°F
Ambient °F70° 90° 110°70° 90° 110°70° 90° 110°70°90°110°70°90°110°70°90°110°
22/25 cu ft1.2 2.0 2.640 55 7525 25 25383838151515151515

Table Caption: This table outlines the no-load performance specifications for a refrigerator, detailing energy consumption, run time, cycle frequency, and compartment temperatures at various ambient temperatures.

Temperature Relationship Test Chart
Evaporator Outlet ±3°FEvaporator Inlet ±3°FSuction Line ±7°FAverage TotalSuction Pressure ±2 PSIGHead Pressure ± 5 PSIG
Ambient °F70°90°70°90°70°90°70°90°70° 90°70°90°
22/25 cu ft-20-17-20-17851051451500085135

Table Caption: This table outlines temperature and pressure readings for a refrigeration system under different ambient conditions (70°F and 90°F) at various points including the evaporator outlet and inlet, and the suction and head lines.

Component Specifications

ComponentSpecifications all parts 115VAC/60HZ unless noted
CompressorBTUH....................................................... Watt.......................................................... Current Lock rotor.................................... Current Full load...................................... Resistance Run windings........................ Resistance Startwindings....................... 695 BTUH EGX70HLC 60 Hz / 113 watts 10.0 amps± 15% 1.6 amps± 15% 4.4 ohms± 15% 6.25 ohms± 15%
RelayTSD2
Compressor run capacitorVolt........................................................... Capacitance.............................................180 VAC 12 µfd ± 10%
Electric damper controlMaximum closing time............................. Temperature Rating................................. RPM.........................................................8 seconds 20°F - 110°F 4.2
ThermistorTemperature............................................. 77°F.......................................................... 36°F.......................................................... 0°F............................................................Resistance 10,000 ohms± 1.8% 29,500 ohms± 1.0% 86,300 ohms± 1.8%
Condenser motorRotation (facing end opposite shaft)........ RPM......................................................... Watt.......................................................... Current.....................................................Clockwise 1120 RPM 3.4 watts±15%@115VAC 0.085 amps± 15%@115VAC
Evaporator fan motorRotation (facing end opposite shaft)........ RPM......................................................... Watt.......................................................... Note: Fan blade must be fully seated on shaft to achieve proper airflow.Clockwise 3000 RPM 5.5 ±15% watts@12VDC
Overload/RelayUlt. trip amps @158°F (70°C)................ Close temperature................................. Open temperature................................. Short time trip (seconds)......................... Short time trip (amps @77°F (25°C).......2.74 amps± 15% 142°F ±16° 248°F ±9° 10 seconds ±5 12 amps ±2amps
Thermostat (Defrost)Volt........................................................... Watt.......................................................... Current..................................................... Resistance across terminals: Above 42°F ±5°....................................... Below 12°F ±7°........................................120/240 VAC 495 watts 5.8/3.75 amps 56kohms Open Closed
Evaporator heaterVolt........................................................... Wattage.................................................... Resistance..............................................115 VAC 435 ±5% watts @115VAC (22cu ft models) 470 ±5% watts @115VAC (20/25cu ft models) 30.4 ±5% ohms (22cu ft models) 29.0 ±5% ohms (20/25cu ft models)
Control boardVolt........................................................... See control board section for diagnostics120 VAC,60HZ
Dual Water ValveWattage....................................................35 watts (Blue Coil) 20 watts (Yellow Coil)
Ice Box FanRotation (facing end opposite shaft)........ RPM......................................................... Watt.......................................................... Note: Fan blade must be fully seated on shaft to achieve proper airflow.Clockwise 3000 RPM 5.5 ±15% watts@12VDC
Light switchType......................................................... Volt........................................................... Current.....................................................SPST NC 125/250 VAC 8 / 4 amps