DA68 01687C
26 CU.FT BOTTOM FREEZER
Technical Data
DISCONNECT POWER CORD BEFORE SERVICING IMPORTANT - RECONNECT ALL GROUNDING DEVICES
IMPORTANT SAFETY NOTICE
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.
ELECTRICAL SPECIFICATIONS
Table Caption: This table provides specifications for a refrigerator's temperature control system, including temperature ranges, defrosting parameters, electrical ratings, and performance data under various ambient conditions.
AIR FLOW
31-51744
This information is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
REFRIGERATION SYSTEM
DA68-01687C REV(0.0)
| Compressor 26 Model | ............................................................897BTU/hr |
|---|---|
| Minimum Equalized Pressure | @90°F................................................................................60 to 65 PSIG |
| @110°F..............................................................................75 | to 82 PSIG |
| REFRIGERANT CHARGE(R134a) 26 Model .............................................................................5.643 | ounces |
**Ta