This is an older family of Saeco devices. The main difference between Odea and Talea is the SBS brewing system of the Talea line. The model designation of the Odea is SUP031 **, the Talea SUP032 **.

2 Domande Visualizza tutte

Saeco Odea Giro Flashing thermostat light.

My Saeco Odea Giro machine has a blinking thermostat light at startup implying the boiler is heating but it never stops blinking and I can’t initiate a brew.

I don’t have easy access to a service centre so I would be grateful if anyone could point me in the right direction on how to solve it.

Rispondi a questa domanda Anch'io ho questo problema

Questa è una buona domanda?

Punteggio 0
Aggiungi un commento

2 Risposte

Risposta Più Utile

@seychellian First help: use the test mode and proof, if the heating really works. If not open the machine. Look for the heating and measure its resistance, it should be 40 Ohm for 230 V models. (Or 10 Ohm for 120 V). If not: replace the heater. Describe your observations, good luck!

Questa risposta è stata utile?

Punteggio 1

1 Commento:

Test mode is telling me that the heating element isn’t working :(

da

Aggiungi un commento

Oh, so you will replace the heating. Open the device, look for the heating. I found the service manual for Odea - but it's in german. The pictures in page 45 will help you. In english here

Questa risposta è stata utile?

Punteggio 0