Salta al contenuto principale

The Audi A4 is a compact executive car produced by the German car manufacturer Audi AG. The 2002-2005 A4 was built on the Volkswagen B6 platform.

16 Domande Visualizza tutte

Ac not blowing cold air.

Had econ light on, found broken grownd wire to pressure switch. Fixed, econ light now off but still no cold air. Have about 70psi on low side of freon and 9vdc going to compressor. Compressor has a solenoid valve, and it does have continuity. Please help, thanks in advance.

Rispondi a questa domanda Anch'io ho questo problema

Questa è una buona domanda?

Punteggio 0
Aggiungi un commento

1 Risposta

Risposta Più Utile

Measure resistance of clutch coil. It should be very low, around 3 ohms. If it's open, the thermal fuse is blown and not a diy repair with some epoxied permanently. With ac turned on, the power wire to the compressor clutch coil should be battery voltage. If the connector is a two wire configuration, measure power to its ground wire and to engine block ground. 70 psi is well above the pressure sensor value to allow power to the compressor. If damage occurs with refrigerant loss, standby pressures below approximately 40 psi will be detected by the pressure sensor, sending a disable signal to the ecm to disable power to the compressor. Loss of refrigerant means loss of lubricating oil. If allowed to run with loss of refrigerant, the compressor will self destruct.

Questa risposta è stata utile?

Punteggio 1
Aggiungi un commento

Aggiungi la tua risposta

Omar Guzman sarà eternamente grato.
Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 5

Ultimi 30 Giorni: 13

Tutti i Tempi: 61