Salta al contenuto principale

Axess TA2513-10WT Camera Replacement

Cosa ti serve

  1. Axess TA2513-10WT Camera Replacement, Back Cover: passo 1, immagine 1 di 1
    • Lay the tablet down on a flat surface with the screen facing up, and the external camera facing upwards and closest to you.

  2. Axess TA2513-10WT Camera Replacement: passo 2, immagine 1 di 3 Axess TA2513-10WT Camera Replacement: passo 2, immagine 2 di 3 Axess TA2513-10WT Camera Replacement: passo 2, immagine 3 di 3
    • Insert the plastic opening tool in the space between the screen and the back cover above the volume buttons.

    • Slide the plastic opening tool gently along the sides.

    • If a small gap is not created between the screen and the back cover, pry gently upward at each of these latching points.

  3. Axess TA2513-10WT Camera Replacement: passo 3, immagine 1 di 1
    • Place the spudger in an open space to keep the back case from shutting while you continue to slide the opening tool.

  4. Axess TA2513-10WT Camera Replacement: passo 4, immagine 1 di 1
    • Remove the back cover with your hands once all points have been unlatched. It should separate completely from the screen that contains the battery and chip components.

  5. Axess TA2513-10WT Camera Replacement, Camera: passo 5, immagine 1 di 1
    • Turn the tablet over. Locate the left screw.

    • Use the magnetic screwdriver to remove the left screw.

  6. Axess TA2513-10WT Camera Replacement: passo 6, immagine 1 di 1
    • There is a bottom screw located to the right of the left screw that was just removed.

    • Remove the bottom screw using the magnetic screwdriver.

  7. Axess TA2513-10WT Camera Replacement: passo 7, immagine 1 di 1
    • Remove the entire plastic cover using either tweezers or your fingers.

  8. Axess TA2513-10WT Camera Replacement: passo 8, immagine 1 di 1
    • Brush the surfaces of the cameras to remove any debris that is present.

  9. Axess TA2513-10WT Camera Replacement: passo 9, immagine 1 di 1
    • There is a black plastic cover on the back of the tablet. It is attached to the ribbon cable.

    • Use tweezers to rotate the black plastic cover 90 degrees upwards.

    • Flip the cover up and pull out the ribbon cable.

  10. Axess TA2513-10WT Camera Replacement: passo 10, immagine 1 di 1
    • Remove the ribbon cable from the port.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Steven Kavanagh

Membro da: 03/24/15

301 Reputazione

3 Guide realizzate

Team

Baylor, Team 6-3, Shaver Spring 2015 Membro di Baylor, Team 6-3, Shaver Spring 2015

BU-SHAVER-S15S6G3

3 Membri

10 Guide realizzate

0 Commenti

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 5

Ultimi 30 Giorni: 5

Tutti i Tempi: 153