Salta al contenuto principale

Why Does The Error Code F17 Mean On A Fisher And Paykel Fridge

I have a fisher and paykel fridge and ocatonally it will beep when you open it and on the screen it will show a wrench and the error code F17. This is for a Fisher And Paykel fridge not a Whirlpool fridge they did not have a Fisher And Paykel fridge for the device at the time this was made.

Rispondi a questa domanda Anch'io ho questo problema

Questa è una buona domanda?

Punteggio 0
Aggiungi un commento

2 Risposte

Risposta Più Utile

Hi @samuraisammy ,

Here’s a link to the service manual for a RF201A. Hopefully is it a close enough model to be of some help.

According to the manual on this page:

Fault Code 17

Reason: The FC fan is drawing less current than is expected. Either the wiring is open circuit or the fan is faulty.

Primary Action: Check the FC fan wiring and connections at both the fan and the power module

Secondary Action: Check the fan. If faulty, replace

Here is the page that shows the FC (Freezer Control) fan.

Hopefully this is of some help.

Questa risposta è stata utile?

Punteggio 2

1 Commento:

@jayeff Ok ill give it a try

da

Aggiungi un commento

Well this is a hoot. Your error code is listed as a freezer fan issue

but next to ALL the error codes it says:

You will require a Service Technician to assist

https://producthelp.fisherpaykel.com/nz/...)

https://producthelp.fisherpaykel.com/nz/...

This is a crock! Let me do some more research, who do they think they are? John Deere or Apple (only WE can fix your machine.

Please give me your exact model number and I’ll see if we can’t find some better help.

Her’s where model numbers are located:

https://producthelp.fisherpaykel.com/Man...

UPDATE

You must be from down under

Looks like it is made by Sears and they do offer parts.

See if this video helps:

https://www.youtube.com/watch?v=r7zEunxy...

Questa risposta è stata utile?

Punteggio 1

3 Commenti:

@mayer Hi thanks for the help the model number is RF201ADUX1

da

I have the same problem with my fridge RF195ADUX1, changed the fan and control panel and still showing the same problem, F17. Any suggestions?

da

@shahramdowl6921

Is the fan operating?

If not is there 12V power getting to the fan from the power board?

If not it may be a wiring problem between the power board and the fan

Here's the wiring diagram from the service manual (yes it is for your model as well, check p.1 for models shown by this manual)

You may have to simulate that the doors are closed for power to be applied to the fan as it is turned off when a door (either door) is open