<item>
<title><![CDATA[Arizant Bair Hugger Model 775: Il dispositivo alla accensione da errore FC-009.]]></title>
<description><![CDATA[<p>Staccato il connettore J4, misurata la resistenza fra cavo bianco e nero si ottengono 66 Ohm, fra bianco e blu da circuito aperto, fra bianco e giallo 260,9 Ohm.</p>

<p>Devo sostituire la resistenza?  Oppure la scheda del circuito di controllo?</p>

<p>Dove posso ordinare i pezzi di ricambio?</p>

<p>Grazie.</p>

<p>⟐ Answered febbraio 12, 2024 at 17:04 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/836438/Il+dispositivo+alla+accensione+da+errore+FC-009.</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/836438</guid>
<pubDate>Mon, 12 Feb 2024 17:04:26 -0700</pubDate>
</item>
<item>
<title><![CDATA[Nellcor N-65: Perchè il dispositivo non si avvia?]]></title>
<description><![CDATA[<p>Il dispositivo è alimentato, il display si accende dopo la pressione del tasto (anche il backlight), mostrando tutte le icone presenti sullo stesso e rimane in questo stato. Non si sente il buzzer, nè i pulsanti non hanno più alcun comando. Mi potete aiutare a capire quale potrebbe essere il problema? Grazie</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/920363/Perch%C3%A8+il+dispositivo+non+si+avvia</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/920363</guid>
<pubDate>Sat, 04 Oct 2025 10:01:23 -0700</pubDate>
</item>
<item>
<title><![CDATA[General Electric eBike III: BMZ Bloks 14d ebike computer motore Brose batteria 750w]]></title>
<description><![CDATA[<p>Vorrei capire se ed in che modo il mio dispositivo è riparabile. Nelle foto si vede voce è e come dovrebbe essere.....</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/915736/BMZ+Bloks+14d+ebike+computer+motore+Brose+batteria+750w</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/915736</guid>
<pubDate>Fri, 05 Sep 2025 21:20:23 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics REMstar Plus M Series: quale centro per le mie necessita?]]></title>
<description><![CDATA[<div class="clearer"></div><div class="headerContainer"><h3 id="Section_devo_fare_una_pulizia_e_revisione_della_mia_respironic_quale_il_centro" class="header">devo  fare una pulizia e revisione  della mia respironic!! quale il centro )???</h3></div>

<p>⟐ Commented gennaio 21, 2023 at 10:38 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/765360/quale+centro+per+le+mie+necessita</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/765360</guid>
<pubDate>Sat, 21 Jan 2023 10:38:30 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: My unit is making a loud noise when I breathe in and out]]></title>
<description><![CDATA[<p>How can I fix the loud noise  when breathe in and out?</p>

<p>⟐ Answered agosto 09, 2026 at 3:28 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/718634/My+unit+is+making+a+loud+noise+when+I+breathe+in+and+out</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/718634</guid>
<pubDate>Sun, 09 Aug 2026 03:28:11 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: Are Software Updates available?]]></title>
<description><![CDATA[<p>ResMed CS reports that due to cellular updates, the CDMA can no longer connect to the cloud.</p>

<p>Is there a way to update either the device SW or the internal modem SW to restore connectivity?</p>

<p>Or a way to give it access to my WiFi so that it can &quot;Phone Home&quot;? ResMed says that I should ask my provider. But why should a respiratory therapist or doctor know that? ResMed should provide this support (or update) to their device.</p>

<p>⟐ Commented giugno 17, 2023 at 13:18 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/765241/Are+Software+Updates+available</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/765241</guid>
<pubDate>Sat, 17 Jun 2023 13:18:11 -0700</pubDate>
</item>
<item>
<title><![CDATA[Drager Ventilator: "Drager Infinity C500" service manual]]></title>
<description><![CDATA[<p>i need the</p>

<p>&quot;Drager Infinity C500&quot; service manual</p>

<p>macilio@alphaservices5.com</p>

<p>⟐ Answer deleted settembre 02, 2022 at 7:06 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/625810/%22Drager+Infinity+C500%22+service+manual</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/625810</guid>
<pubDate>Fri, 02 Sep 2022 07:06:30 -0700</pubDate>
</item>
<item>
<title><![CDATA[Blood pressure monitor: Need a device that will monitor blood pressure during the day]]></title>
<description><![CDATA[<p>I having problems with adjusting my blood pressure medications.</p>

<p>Does anyone know of a wrist device that will monitor blood pressure during the day so that it will alert me to either check it with a sphygmomanometer or take my meds.</p>

<p>This would help prevent me from going off on rants while answering iFixit questions ;-)  And a lot of you are aware I can do that!</p>

<p><strong>UPDATE 9/21/18</strong></p>

<p>I was in hopes that the new iWatch 4 might help monitor my atrial fibrillation (aFib).  I was just about to order one but found this article stating that Apple has promised it for later:</p>

<p><strong>Buying an Apple Watch 4 now for EKG and AFib features may leave you heartbroken</strong></p>

<p><a href="https://www.zdnet.com/article/buying-an-apple-watch-4-now-for-ekg-and-afib-features-may-leave-you-heartbroken/" rel="nofollow noopener noreferrer" title="https://www.zdnet.com/article/buying-an-apple-watch-4-now-for-ekg-and-afib-features-may-leave-you-heartbroken/">https://www.zdnet.com/article/buying-an-...</a></p>

<p>⟐ Answered giugno 21, 2020 at 5:30 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/366615/Need+a+device+that+will+monitor+blood+pressure+during+the+day</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/366615</guid>
<pubDate>Sun, 21 Jun 2020 05:30:02 -0700</pubDate>
</item>
<item>
<title><![CDATA[Siare Siaretron 4000: siare 4000 service manual]]></title>
<description><![CDATA[<p>we had a problem about the flow sensor of siare 4000 if we calibrate the calibration result was failed  and we notice that there's  rust in the sensor any solution to this problem. we  hope that you can help us.thank you</p>

<p>⟐ Answer edited ottobre 08, 2024 at 22:33 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/682749/siare+4000+service+manual</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/682749</guid>
<pubDate>Tue, 08 Oct 2024 22:33:06 -0700</pubDate>
</item>
<item>
<title><![CDATA[SLE Ventilator: What is the service password]]></title>
<description><![CDATA[<p>I need to calibrate so I need the service password for the SLE 5000 ventilator</p>

<p>⟐ Answer edited maggio 18, 2024 at 22:01 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/625946/What+is+the+service+password</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/625946</guid>
<pubDate>Sat, 18 May 2024 22:01:17 -0700</pubDate>
</item>
<item>
<title><![CDATA[VersaMed iVent 201: O2 calibration incorrect what may be wrong?]]></title>
<description><![CDATA[<p>why do i keep getting o2 system calibration incorrect even when i replace the o2 sensor and block inlet port?</p>

<p>⟐ Answered agosto 03, 2020 at 11:06 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/628887/O2+calibration+incorrect+what+may+be+wrong</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/628887</guid>
<pubDate>Mon, 03 Aug 2020 11:06:52 -0700</pubDate>
</item>
<item>
<title><![CDATA[Hearing Aid: How can I replace my rechargeable batteries in my hearing aids?]]></title>
<description><![CDATA[<div class="imageBox imageBox_left"><img src="https://guide-images.cdn.ifixit.com/igi/vECspIIipEJEkgdB.standard" width="127" height="225" class="hasMenu hasLarge" alt="Immagine" onclick="window.open(&quot;https:\/\/guide-images.cdn.ifixit.com\/igi\/vECspIIipEJEkgdB.huge&quot;, '', 'width=675,height=1200')" /></div>

<p>How to replace rechargeable batteries in hearing aids?</p>

<p>⟐ Answered aprile 21, 2026 at 9:45 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/878715/How+can+I+replace+my+rechargeable+batteries+in+my+hearing+aids</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/878715</guid>
<pubDate>Tue, 21 Apr 2026 09:45:48 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics Millennium: It beeps service required alarm with low oxygen]]></title>
<description><![CDATA[<p>My millennium m10 oxygen concentrator low oxygen light shows.... Then after about 2minutes, the service required alarm sounds continously..... What should I do???</p>

<p>⟐ Answered giugno 06, 2024 at 16:40 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/731686/It+beeps+service+required+alarm+with+low+oxygen</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/731686</guid>
<pubDate>Thu, 06 Jun 2024 16:40:51 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: Very high leak rate on report screen]]></title>
<description><![CDATA[<p>I get very high leak rates 40 to 70 L/min indicated with no mask seal alert and no warnings. Mask,tank,and tube all check good with no leaks</p>

<p>⟐ Answered maggio 24, 2023 at 9:26 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/705963/Very+high+leak+rate+on+report+screen</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/705963</guid>
<pubDate>Wed, 24 May 2023 09:26:25 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: What is this part called (or part#) found on the resmed AirSense10?]]></title>
<description><![CDATA[<p>It is found inside body of the unit where the reservoir goes and mates with it and the removable/replaceable elbow.  It is only accessible after disassembly and once removing the air pump.  mine is old and covered in calcium which i am cleaning now but would like to replace as it makes whistling noises while im sleeping which wakes me up every night!  THANK YOU!!!</p>

<div class="imageBox imageBox_left"><img src="https://guide-images.cdn.ifixit.com/igi/lMWUQ3ojcVJNYtZK.standard" width="169" height="225" class="hasMenu hasLarge" alt="Immagine" onclick="window.open(&quot;https:\/\/guide-images.cdn.ifixit.com\/igi\/lMWUQ3ojcVJNYtZK.huge&quot;, '', 'width=900,height=1200')" /></div>

<div class="imageBox imageBox_left"><img src="https://guide-images.cdn.ifixit.com/igi/gYnkTmFCDbWKlMgQ.standard" width="169" height="225" class="hasMenu hasLarge" alt="Immagine" onclick="window.open(&quot;https:\/\/guide-images.cdn.ifixit.com\/igi\/gYnkTmFCDbWKlMgQ.huge&quot;, '', 'width=900,height=1200')" /></div>

<div class="imageBox imageBox_left"><img src="https://guide-images.cdn.ifixit.com/igi/SKXwD2pIY3kiXDWN.standard" width="169" height="225" class="hasMenu hasLarge" alt="Immagine" onclick="window.open(&quot;https:\/\/guide-images.cdn.ifixit.com\/igi\/SKXwD2pIY3kiXDWN.huge&quot;, '', 'width=901,height=1200')" /></div>

<p>⟐ Commented settembre 30, 2022 at 16:08 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/680266/What+is+this+part+called+(or+part%23)+found+on+the+resmed+AirSense10</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/680266</guid>
<pubDate>Fri, 30 Sep 2022 16:08:22 -0700</pubDate>
</item>
<item>
<title><![CDATA[Philips Respironics V200 Esprit: How can I fix 'trending not available'notification on display?]]></title>
<description><![CDATA[<p>Any time the ventilator is turned on it says ‘trending not available see the operator manual’ and some of the front panel button are not functional including alarm. According to operator manual,I checked the PCMCIA card and it seems to be  ok.so what should I do?It is Philips V200 ventilator</p>

<p>⟐ Answered novembre 17, 2020 at 16:02 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/629887/How+can+I+fix+&#039;trending+not+available&#039;notification+on+display</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/629887</guid>
<pubDate>Tue, 17 Nov 2020 16:02:30 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics EverFlo: no air produced even though green light is on]]></title>
<description><![CDATA[<p>The concentrator turns on, all three lights come on at first for a few seconds, then only green. However, there is no O2 being produced, the gauge stays at the bottom, no tubing or cannula attached.</p>

<p>Before this the red alarm light and sound came on after a few seconds and stayed on, so I replaced the filter. Now the concentrator has the above condition with the new filter and also with the old filter put back.</p>

<p>After running the concentrator for several minutes with the new filter (which does not seem to be the problem) the red light comes on and the alarm sounds continuously until I turn the machine off.</p>

<p>⟐ Answered giugno 27, 2023 at 16:58 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/725386/no+air+produced+even+though+green+light+is+on</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/725386</guid>
<pubDate>Tue, 27 Jun 2023 16:58:47 -0700</pubDate>
</item>
<item>
<title><![CDATA[Blood Pressure Monitor: How to fix disconnected mercury in sphygmomanometer]]></title>
<description><![CDATA[<p>My sphygmomanometer suddenly has its mercury disconnected,meaning that there are like air gaps in it,  which results in wrong readings, I think there is a way to fix it, but do not know how??</p>

<p>it's really important to me, and I almost daily need to use it. and do not want to buy another on.</p>

<p>⟐ Commented dicembre 23, 2021 at 5:56 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/368104/How+to+fix+disconnected+mercury+in+sphygmomanometer</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/368104</guid>
<pubDate>Thu, 23 Dec 2021 05:56:52 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: Resmed Aircurve 10 ASV has no power to device.]]></title>
<description><![CDATA[<p>My Resmed CPAP  Aircurve 10 asv won’t power on. Can I open it and check for blown fuse or other problem?</p>

<p>⟐ Commented maggio 13, 2021 at 9:32 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/691864/Resmed+Aircurve+10+ASV+has+no+power+to+device.</link>
<guid isPermaLink="false" >https://it.ifixit.com/Risposte/View/691864</guid>
<pubDate>Thu, 13 May 2021 09:32:39 -0700</pubDate>
</item>
<item>
<title><![CDATA[Pulse Oximeter: Screen is not getting on]]></title>
<description><![CDATA[<p>Screen is dead. Have changed battery</p>

<p>⟐ Answered febbraio 26, 2021 at 2:45 GMT-7</p>]]></description>
<link>https://it.ifixit.com/Risposte/Visualizza/680892/Screen+is+not+getting+on</link>