Introduzione

The motor is the driving force of the blender. It sits in a metal container and is surrounded by copper wire.

Remove the glass container and place the blender upside down on a solid surface. Remove the four rubber feet using the needle nose pliers. Remove the four #7.5 Phillips 25mm screws that were located underneath the rubber feet using the Phillips #2 screwdriver.
  • Remove the glass container and place the blender upside down on a solid surface.

  • Remove the four rubber feet using the needle nose pliers.

  • Remove the four #7.5 Phillips 25mm screws that were located underneath the rubber feet using the Phillips #2 screwdriver.

Aggiungi Commento

Lift the back panel up, sliding it along the power cord.
  • Lift the back panel up, sliding it along the power cord.

Aggiungi Commento

Remove the two #5 Phillips 95 mm machine screws using the Phillips #2 screwdriver. Remove the rubber O-ring by lifting it up. Remove the ribbon cable from the chassis by lifting it up.
  • Remove the two #5 Phillips 95 mm machine screws using the Phillips #2 screwdriver.

  • Remove the rubber O-ring by lifting it up.

  • Remove the ribbon cable from the chassis by lifting it up.

Aggiungi Commento

Unhook the white wire that is looped around the peg by pulling it out of the clip. Repeat this process with the red wire on the other side of the chassis. Remove the end cap using the 8" needle nose pliers.
  • Unhook the white wire that is looped around the peg by pulling it out of the clip.

  • Repeat this process with the red wire on the other side of the chassis.

  • Remove the end cap using the 8" needle nose pliers.

  • Pull up the fan chassis.

Aggiungi Commento

Remove the fan by lifting it upwards.
  • Remove the fan by lifting it upwards.

  • This step is difficult and requires force. Use of both hands is recommended.

Aggiungi Commento

Use the needle nose pliers to turn the coupling clockwise to loosen it.
  • Use the needle nose pliers to turn the coupling clockwise to loosen it.

Aggiungi Commento

Rotate the blender 90 degrees clockwise.
  • Rotate the blender 90 degrees clockwise.

  • Remove the two #8 Phillips 12 mm screws using the Phillips #2 screwdriver.

Aggiungi Commento

Slide the knife in the metal loop holding the insulation before the white copper wire, and wiggle the knife back and forth until it loosens.
  • Slide the knife in the metal loop holding the insulation before the white copper wire, and wiggle the knife back and forth until it loosens.

  • Pull the wire out from the metal loop that you loosened.

Aggiungi Commento

Lift the motor up out of the chassis.
  • Lift the motor up out of the chassis.

Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.

Un'altra persona ha completato questa guida.

Cameron Geehr

Membro da: 28/09/2014

681 Reputazione

6 Guide realizzate

Team

Cal Poly, Team 12-5, Forte Fall 2014 Membro di Cal Poly, Team 12-5, Forte Fall 2014

CPSU-FORTE-F14S12G5

5 Membri

6 Guide realizzate

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 1

Ultimi 7 Giorni: 11

Ultimi 30 Giorni: 59

Tutti i Tempi: 1,704