Introduzione

Removing the frame will allow access to the eyes and solenoid should they need replacement.

Parti

Nessuna parte richiesta.

Firmly grasp hold of the ring on the bottom of the 90 degree silver fitting on the front of the gun. Pull hard, but slowly, on the macroline where it comes out of silver piece until it comes out.
  • Firmly grasp hold of the ring on the bottom of the 90 degree silver fitting on the front of the gun.

  • Pull hard, but slowly, on the macroline where it comes out of silver piece until it comes out.

  • The macroline is the black hose connecting the regulator to the tank connection.

Aggiungi Commento

Remove the regulator by unscrewing it in a clockwise direction. Remove the regulator by unscrewing it in a clockwise direction.
  • Remove the regulator by unscrewing it in a clockwise direction.

Aggiungi Commento

Use the 5/64" hex key to remove the screw shown. Remove the grip panel by gently holding the bottom of the panel and lifting the panel off.
  • Use the 5/64" hex key to remove the screw shown.

  • Remove the grip panel by gently holding the bottom of the panel and lifting the panel off.

  • If you are only replacing the battery, skip the next step.

  • The screws in this guide are interchangeable with those shown in the Eyes replacement guide.

Aggiungi Commento

Flip the marker over and use the 5/64" hex key to remove the screw shown.
  • Flip the marker over and use the 5/64" hex key to remove the screw shown.

  • Remove the grip panel by gently holding the bottom of the panel and lifting the panel off.

Aggiungi Commento

Carefully remove the 9V battery and connector. Remove the 9V battery from the connector.
  • Carefully remove the 9V battery and connector.

  • Remove the 9V battery from the connector.

Aggiungi Commento

Carefully disconnect the three connectors from the circuit board. Don't worry about remembering which direction the connectors go in, they will not fit in the board in the wrong direction.
  • Carefully disconnect the three connectors from the circuit board.

  • Don't worry about remembering which direction the connectors go in, they will not fit in the board in the wrong direction.

Aggiungi Commento

Use the 1/8" hex key to remove the two dome-headed screws by rotating them counter-clockwise. Use the 1/8" hex key to remove the two dome-headed screws by rotating them counter-clockwise.
  • Use the 1/8" hex key to remove the two dome-headed screws by rotating them counter-clockwise.

Aggiungi Commento

Be very careful during the step to avoid damage to the solenoid or wiring.
  • Be very careful during the step to avoid damage to the solenoid or wiring.

  • Gently separate the top and bottom of the marker.

Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.

nicholasj6

Membro da: 14/10/2014

261 Reputazione

2 Guide realizzate

Team

Cal Poly, Team 10-42, Amido Fall 2014 Membro di Cal Poly, Team 10-42, Amido Fall 2014

CPSU-AMIDO-F14S10G42

5 Membri

7 Guide realizzate

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 0

Ultimi 30 Giorni: 5

Tutti i Tempi: 210