Adjusting the alarm glass breakage microphone sensitivity

Cosa ti serve

  1. Adjusting the alarm glass breakage microphone sensitivity: passo 2, immagine 1 di 1
    • Once the glove box is out of the way, it's easy to spot the alarm unit. The green connector will be plugged into it. I had already unplugged it when I took this picture.

  2. Adjusting the alarm glass breakage microphone sensitivity: passo 3, immagine 1 di 1
    • It may be stubborn to get out because it is stuck down with double stick foam pads.

  3. Adjusting the alarm glass breakage microphone sensitivity: passo 4, immagine 1 di 1
    • Remove the 4 screws (may be under the foam strips). This is the bottom of the circuit board.

  4. Adjusting the alarm glass breakage microphone sensitivity: passo 5, immagine 1 di 1
    • Turn the board over and locate the 2 position dip switch.

    • This dip switch adjusts the glass breakage microphone sensitivity

    • Sensitivity settings:

    • 1 off & 2 off = high

    • 1 on & 2 off = mid (factory setting)

    • 1 off & 2 on = low

    • 1 on & 2 on = super low

Conclusione

To reassemble your device, follow these instructions in reverse order.