Traduzione in corso passo 5
-
Use a razor knife and carefully cut away the silicon insulation around the thermal cutout.
-
Note that the cutout is a 115 degree C 2 amp device. I replaced it with a Panasonic EYP-2BN110 which is available from DataAlchemy on Amazon Marketplace.
-
Clip the old unit out and melt a blob of solder on the wires that stick out. Then clip short the leads of the new thermal cutout so that they just reach the exposed wires.
-
Hold the thermal cutout as far away from the device as possible with needle-nose pliers as a heatsink so that the soldering iron doesn't blow the fuse and quickly solder the fuse in place.
-
Now thread a bit of electrical insulation around the cutout to cover the exposed wires. Do not use more than a layer or the cutout may not operate when it is needed.
I tuoi contributi sono usati su licenza in base alla licenza open source Creative Commons.