Introduzione

The requirements for this guide are the right tools and the device itself. The motherboard should be removed when trying to access the internal components of the recorder.

Place device face up and pry off the four knobs using the flat end of the plastic opening tool.
  • Place device face up and pry off the four knobs using the flat end of the plastic opening tool.

  • You may need to stabilize the device with the other hand.

Aggiungi Commento

With device facedown, lift the four rubber feet from the device using tweezers or fingernails.
  • With device facedown, lift the four rubber feet from the device using tweezers or fingernails.

Aggiungi Commento

  • With device still facedown, unscrew six (PH #1), 9mm screws; two located in center of back side of device right above the battery cover, and four under the rubber feet.

  • An electronics screwdriver small enough to fit in hole (4mm diameter), but long enough to reach the screws (at least 2cm) will be required to unscrew the screws.

Aggiungi Commento

  • With the bottom of the device on a table, lift the top of the device and gently place it aside.

Aggiungi Commento

  • Unscrew three (PH #1), 7mm screws from the display backing and gently flip over.

The red highlight circle for the top screw in the first picture of step 5 is in the wrong place. The screw is actually on the right side, just slightly above the bottom left one. The top screw is shown still attached in the second and third picture of the series.

brian - Replica

  • Using a plastic opening tool, unlatch the clip and carefully unplug the ribbon connector from the device.

  • Set the button board aside.

Aggiungi Commento

  • Unscrew four (PH #1), 8mm screws from the motherboard.

Aggiungi Commento

  • Disconnect wire from motherboard using tweezers.

  • Do not touch the motherboard with metal tweezers. Only touch the plastic part of the plugged-in wire.

Aggiungi Commento

  • Turn device 180 degrees to unscrew two (PH #1), 8mm screws from the mic connector.

Aggiungi Commento

  • Gently remove three ribbon connectors from the device.

  • The first is connected to the mic connector.

  • The second is connected to the base of the device, and the third is connected to the power switch on the side of the device; turn the device 180 degrees, and the connectors are near the top of the device next to the "LINE OUT" plug-in (directly behind the device display).

  • It's best to use tweezers to remove the two ribbon connectors behind the display.

  • Avoid touching anything but the ribbon connectors with the metal tweezers.

Aggiungi Commento

  • Gently lift the motherboard from the base of the device and set aside.

Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.

Cheryl Avery

Membro da: 14/02/2018

154 Reputazione

1 Guida realizzata

Team

USF Tampa, Team S5-G2, Eyestone Spring 2018 Membro di USF Tampa, Team S5-G2, Eyestone Spring 2018

USFT-EYESTONE-S18S5G2

4 Membri

8 Guide realizzate

Good night Mr.

I have a H6 recorder H.6 handy recorder, never use, but the battery stay in and it leak in the box.

When i remove the leaking battery, and i renew the battery the recorder did not start. According a technician the aparatus have to be open and chance the plate, but we does not have those technician on the island. please advice.

Edgar.

leito - Replica

hello, i just have a question, where can i find this parts?

tahitibob57 - Replica