Introduzione

Occasionally the dryer may become too loud as a result of a faulty motor. This guide details the steps taken to replace the motor. Disassembly of the device requires a special bit for removal of tamper-proof screws.

  1. To change the motor, start by removing  the metal casing.
    • To change the motor, start by removing the metal casing.

    • Using the special bit, remove the large screws at the bottom of the casing.

    • To remove the case, lift the indicated spot with your hands.

    • The direction for turning the screws is different than what was indicated on the small sticker above the hole.

    Aggiungi Commento

  2. Remove the three 1/2" Ph1 screws at the bottom of the red fan cap.
    • Remove the three 1/2" Ph1 screws at the bottom of the red fan cap.

    • Turn over the device.

    • Push the red tabs on the back of the unit with medium to heavy pressure, using a small prier.

    • Carefully remove the cap, to prevent damage to the sensor.

    Aggiungi Commento

    • Remove both 3/8" Ph2 screws attached to the grey belt at the top and bottom.

    • Lift the grey belt away. This gives access to the server board.

    Aggiungi Commento

  3. Diffondi allegria Fixmas
    Ottieni $12 sul tuo acquisto di $50 o più con il codice FIXMAS12
    Diffondi allegria Fixmas
    Ottieni $12 sul tuo acquisto di $50 o più con il codice FIXMAS12
    • Use a plastic opening tool to remove the two pink capped wires in the upper left corner of the server board.

    Aggiungi Commento

    • Remove the brass nut from its bolt using a 10mm wrench.

    • Once the nut is free, disconnect the green wire.

    Aggiungi Commento

    • Remove the rainbow ribbon cable using a plastic opening tool.

    • Remove the 1/2" Ph1 screw from the center of the circuit board.

    Aggiungi Commento

    • Remove the four 3/4" Ph2 screws from the back of the device body.

    • Separate the motor housing from the device body.

    • Ensure that all wires connecting the motor housing and motherboard are disconnected before removing the component.

    Aggiungi Commento

    • Remove the four 1/2" Ph2 screws from the filter.

    • Pull the filter plate away to reveal the motor.

    Aggiungi Commento

    • Pull the motor out of the housing.

    • Be sure to feed the wires through the slot as you pull the motor out.

    Aggiungi Commento