Introduzione

The motor drives the clipper blades. Motors can wear out after extended use. Replacing a worn-out motor can extend the longevity of this device.

  1. Remove the two 5.0 mm JIS #1 screws to loosen the cutting blades.
    • Remove the two 5.0 mm JIS #1 screws to loosen the cutting blades.

    • Make sure your device is not connected to power before you begin.

  2. Lift the bottom blade straight up from the device body to remove it.
    • Lift the bottom blade straight up from the device body to remove it.

  3. Remove the three 9.0 mm JIS #1 screws attaching the base of the blade assembly to the body.
    • Remove the three 9.0 mm JIS #1 screws attaching the base of the blade assembly to the body.

  4. Lift the base of blade assembly straight up off of the body.
    • Lift the base of blade assembly straight up off of the body.

  5. Spedizione gratuita per tutti gli ordini superiori a 100 US$ o contenenti un Kit Attrezzi Pro Tech!

    Sfoglia il Nostro Negozio
  6. Remove the two 12.0 mm JIS #1 screws on the back of the device body.
    • Remove the two 12.0 mm JIS #1 screws on the back of the device body.

  7. Remove the 13.0 mm Phillips #2 screw on the side of the device body.
    • Remove the 13.0 mm Phillips #2 screw on the side of the device body.

    • This screw is located on the opposite side of the body from the switch.

  8. Remove the spring  on the side of the body using tweezers.
    • Remove the spring on the side of the body using tweezers.

  9. Pry the body case off of the device using a spudger.
    • Pry the body case off of the device using a spudger.

  10. Lift power cord tab (black wire) from slot on motor base.
    • Lift power cord tab (black wire) from slot on motor base.

  11. Lift switch tab (teal wire) from slot on motor base.
    • Lift switch tab (teal wire) from slot on motor base.

  12. Remove two 23.0 mm JIS #1 screws attaching motor base to device body.
    • Remove two 23.0 mm JIS #1 screws attaching motor base to device body.

  13. Lift motor base straight up from device body to remove.
    • Lift motor base straight up from device body to remove.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Un'altra persona ha completato questa guida.

Ashley Dale

Membro da: 09/11/2017

231 Reputazione

2 Guide realizzate

Team

IUPUI, Team S7-G3, Baechle Fall 2017 Membro di IUPUI, Team S7-G3, Baechle Fall 2017

IUPUI-BAECHLE-F17S7G3

3 Membri

4 Guide realizzate

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 3

Ultimi 30 Giorni: 10

Tutti i Tempi: 283