Salta al contenuto principale

Rival CM4015 Power Cable Replacement

Cosa ti serve

  1. Rival CM4015 Power Cable Replacement, Base Plate: passo 1, immagine 1 di 2 Rival CM4015 Power Cable Replacement, Base Plate: passo 1, immagine 2 di 2
    • Remove the three 16 mm tri-point screws from the base plate.

  2. Rival CM4015 Power Cable Replacement: passo 2, immagine 1 di 2 Rival CM4015 Power Cable Replacement: passo 2, immagine 2 di 2
    • Remove the base plate by pressing the plastic body away from the metal plate with your thumbs.

  3. Rival CM4015 Power Cable Replacement, Power Cable: passo 3, immagine 1 di 1
    • Remove the two 8mm Phillips screws from the plastic body.

  4. Rival CM4015 Power Cable Replacement: passo 4, immagine 1 di 1
    • Pull the cord and cut the black and red wires across the black heat shrink.

    • Be careful when soldering the new power cable.

Conclusione

To reassemble your device, follow these instructions in reverse order.