Parti

Nessuna parte richiesta.

  1. Before disassembly, make sure that the device is unplugged.
    • Before disassembly, make sure that the device is unplugged.

    • Unscrew the two 17.83 mm black screws located on the handle.

    Aggiungi Commento

  2. Separate the shell from the main component.
    • Separate the shell from the main component.

    • Make sure that the each piece is free from debris.

    Aggiungi Commento

    • Continue to pull the components apart.

    • For reassembly, put the silver encasing on before the the black cover.

    Aggiungi Commento

    • The heating element is the group of tightly coiled bronze wires behind the vent hose as well as the silver coils.

    • Make sure that there are no breaks or debris obstructing the wires of the heating element.

    Aggiungi Commento

    • To test the heating element, use a digital multimeter.

    • Set the multimeter to 200 under ACV.

    • Bring the ends of the multimeter toward the two lead wires.

    • If the circuit between the wires is closed, the numbers on the multimeter should keep changing.

    • If the numbers are not changing, replace the heating element.

    • If the circuit is closed, check the thermal cutout.

    Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.