Introduzione

Water damage or a faulty electrical opponent may make the Pioneer Elite Pro-R06U shut off intermittently or fail to power on. Removing the faulty board and installing a new one should get the receiver back up and running.

Parti

Nessuna parte richiesta.

Remove the two 6.4 mm Phillips screws on each side of the device's casing.
  • Remove the two 6.4 mm Phillips screws on each side of the device's casing.

Aggiungi Commento

Remove the three 6.5 mm Phillips screws on the back of the device casing.
  • Remove the three 6.5 mm Phillips screws on the back of the device casing.

Aggiungi Commento

  • Grip the front panel in one hand and the back of the casing in the other. Pull the casing back, and slide it up and away from the inner box.

Aggiungi Commento

  • Gently pull upward and unplug cables D4 and D5.

Aggiungi Commento

  • Remove the two 7/16 inch Phillips screws to the left and right of the power supply port.

  • Remove three 5/16 inch Phillips screws from the corners of the board.

Aggiungi Commento

  • Remove the power supply board by pulling it toward the interior of the device then lifting.

Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.