Introduzione

This guide is for the Philips Sonicare 2 series HX6211/46 toothbrush. It shows you how to replace the motor for this toothbrush. He is a link for a guide how to soldering which will be needed for this guide. How To Solder and Desolder Connections

  1. Remove brush on top of device.
    • Remove brush on top of device.

  2. Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.
    • Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.

    • Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.

    • Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.

    • Next you will be able to remove the internal electronic mechanism as shown in the figure.

    • Remove the white battery cover as shown in the figure.

    • Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .

    • Disassemble the device. Remove the plastic piece over the brush attachment as shown. Object can be removed by hand as shown. No tool is required.

    • Desolder the motor from the circuit board at the two locations shown.

    • Remove the bad motor.

Linea Traguardo

Jonathan Jarvis

Membro da: 01/04/2016

452 Reputazione

4 Guide realizzate

Team

IUPUI, Team S6-G2, Baechle Fall 2017 Membro di IUPUI, Team S6-G2, Baechle Fall 2017

IUPUI-BAECHLE-F17S6G2

3 Membri

4 Guide realizzate

Visualizza Statistiche:

Ultime 24 Ore: 1

Ultimi 7 Giorni: 10

Ultimi 30 Giorni: 37

Tutti i Tempi: 435