Holmes HEH8031 Safety Weight Replacement

Cosa ti serve

  1. Holmes HEH8031 Safety Weight Replacement, Housing: passo 1, immagine 1 di 1
    • Ensure the device is unplugged from the wall outlet.

  2. Holmes HEH8031 Safety Weight Replacement: passo 2, immagine 1 di 1
    • Remove eight 12-mm Phillips #2 screws from the back cover.

  3. Holmes HEH8031 Safety Weight Replacement: passo 3, immagine 1 di 2 Holmes HEH8031 Safety Weight Replacement: passo 3, immagine 2 di 2
    • Turn heater over so the controls are facing up.

    • Lift the front housing away from the back of the fan and slowly fold the front housing back down to the floor.

    • Internal wires are connected to both halves of the housing. Be careful when separating the housing.

  4. Holmes HEH8031 Safety Weight Replacement, Circuit Board Removal: passo 4, immagine 1 di 1
    • Remove four 12mm Phillips #2 screws from the circuit board.

  5. Holmes HEH8031 Safety Weight Replacement, Safety Weight: passo 5, immagine 1 di 2 Holmes HEH8031 Safety Weight Replacement, Safety Weight: passo 5, immagine 2 di 2
    • Remove wires from safety weight, as shown.

    • Pull upward on the blue connectors.

    • If connectors are tough to remove, try wiggling while pulling upward.

  6. Holmes HEH8031 Safety Weight Replacement: passo 6, immagine 1 di 1
    • Unscrew the Phillips #2 10 mm screw from the safety weight on the rear housing panel.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Deanna Jack

Membro da: 10/12/16

333 Reputazione

4 Guide realizzate

Team

IUPUI, Team 2-1, Baechle Fall 2016 Membro di IUPUI, Team 2-1, Baechle Fall 2016

IUPUI-BAECHLE-F16S2G1

4 Membri

16 Guide realizzate

0 Commenti

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 2

Ultimi 30 Giorni: 5

Tutti i Tempi: 539