HoMedics TotalComfort UHE-CM18 Control Panel Replacement

Cosa ti serve

  1. HoMedics TotalComfort UHE-CM18 Control Panel Replacement, Control Panel: passo 1, immagine 1 di 2 HoMedics TotalComfort UHE-CM18 Control Panel Replacement, Control Panel: passo 1, immagine 2 di 2
    • Lift up the water tank and separate it from the humidifier.

    • Flip the humidifier over to its underside.

  2. HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 2, immagine 1 di 2 HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 2, immagine 2 di 2
    • Use the Phillips #1 screwdriver to remove the two 7 mm screws that secure the AC power plug.

    • Remove the AC power plug cover.

  3. HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 3, immagine 1 di 2 HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 3, immagine 2 di 2
    • Remove the remaining four 7mm screws that hold the bottom cover.

    • Remove the bottom cover.

  4. HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 4, immagine 1 di 3 HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 4, immagine 2 di 3 HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 4, immagine 3 di 3
    • Disconnect the two white cables by pushing down the center tab at the end and pulling it out of its socket.

  5. HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 5, immagine 1 di 2 HoMedics TotalComfort UHE-CM18 Control Panel Replacement: passo 5, immagine 2 di 2
    • Remove the three 7mm screws that attach the control panel to the case.

    • Remove the control panel from the case.

Conclusione

To reassemble your device, follow these instructions in reverse order.