Introduzione

Gear allows the scanner arm to follow the grain track and scan the document. Before replacing the gear make sure the printer is unplugged.

Parti

Nessuna parte richiesta.

  1. Unscrew and remove the center 13mm T10 Torx Security screw using the iFixit screwdriver Unscrew and remove the top right 13mm T10 Torx Security screw using the iFixit screwdriver Unscrew and remove the bottom left 13mm T10 Torx Security screw using the iFixit screwdriver
    • Unscrew and remove the center 13mm T10 Torx Security screw using the iFixit screwdriver

    • Unscrew and remove the top right 13mm T10 Torx Security screw using the iFixit screwdriver

    • Unscrew and remove the bottom left 13mm T10 Torx Security screw using the iFixit screwdriver

  2. Unscrew and remove the bottom 13mm TR10 Torx Security screws using the iFixit screwdriver Unscrew and remove the bottom 13mm TR10 Torx Security screws using the iFixit screwdriver Unscrew and remove the bottom 13mm TR10 Torx Security screws using the iFixit screwdriver
    • Unscrew and remove the bottom 13mm TR10 Torx Security screws using the iFixit screwdriver

  3. Unscrew and remove the top right13mm TR10 Torx Security screws using the iFixit screwdriver Unscrew and remove the top right13mm TR10 Torx Security screws using the iFixit screwdriver Unscrew and remove the top right13mm TR10 Torx Security screws using the iFixit screwdriver
    • Unscrew and remove the top right13mm TR10 Torx Security screws using the iFixit screwdriver

  4. Spedizione gratuita per tutti gli ordini superiori a 100 US$ o contenenti un Kit Attrezzi Pro Tech!

    Sfoglia il Nostro Negozio
  5. Unscrew and remove the upper 13mm TR10 Torx  Security screw using the iFixit screwdriver Unscrew and remove the upper 13mm TR10 Torx  Security screw using the iFixit screwdriver
    • Unscrew and remove the upper 13mm TR10 Torx Security screw using the iFixit screwdriver

  6. Remove the scanner lid and plate (top cover). Locate the Scanner Arm Actuator.
    • Remove the scanner lid and plate (top cover).

    • Locate the Scanner Arm Actuator.

  7. Locate the Scanner Arm Accuator and remove. Locate the Scanner Arm Accuator and remove.
    • Locate the Scanner Arm Accuator and remove.

  8. Unscrew and remove the 13mm TR10 Torx  Security screw in the center of the gear using the iFixit screwdriver Unscrew and remove the 13mm TR10 Torx  Security screw in the center of the gear using the iFixit screwdriver
    • Unscrew and remove the 13mm TR10 Torx Security screw in the center of the gear using the iFixit screwdriver

  9. Locate the white gear and remove. Locate the white gear and remove. Locate the white gear and remove.
    • Locate the white gear and remove.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Un'altra persona ha completato questa guida.

Elizabeth Surface

Membro da: 26/08/2015

1.386 Reputazione

9 Guide realizzate

Team

USF Tampa, Team 4-6, Meier Fall 2015 Membro di USF Tampa, Team 4-6, Meier Fall 2015

USFT-MEIER-F15S4G6

4 Membri

9 Guide realizzate

It is not possible to get to the bottom two screws out without tilting the scan bed/cover back more. To that, I had to disconnect the swing arm on the right side of the scanner bed/cover. After that, all worked smoothly. Thank you.

Ron - Replica

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 0

Ultimi 30 Giorni: 14

Tutti i Tempi: 316