Salta al contenuto principale

FujiFilm FinePix A340 Flash Unit Replacement

Cosa ti serve

  1. FujiFilm FinePix A340 Flash Unit Replacement, Outer Case: passo 1, immagine 1 di 1
    • To prevent the danger of electric shock, remove the batteries before continuing to the next steps.

    • Slide the battery cover to the side to release the batteries.

  2. FujiFilm FinePix A340 Flash Unit Replacement: passo 2, immagine 1 di 3 FujiFilm FinePix A340 Flash Unit Replacement: passo 2, immagine 2 di 3 FujiFilm FinePix A340 Flash Unit Replacement: passo 2, immagine 3 di 3
    • Remove five screws from the camera casing using a tri-point Y0 screwdriver.

  3. FujiFilm FinePix A340 Flash Unit Replacement: passo 3, immagine 1 di 2 FujiFilm FinePix A340 Flash Unit Replacement: passo 3, immagine 2 di 2
    • Grab the case with your hands and slowly pull back the outer casing.

  4. FujiFilm FinePix A340 Flash Unit Replacement, LCD Screen: passo 4, immagine 1 di 1
    • Locate the LCD screen and anchoring screw.

    • Remove screw.

  5. FujiFilm FinePix A340 Flash Unit Replacement: passo 5, immagine 1 di 1
    • Carefully pull the LCD screen away from the board it is connected to.

  6. FujiFilm FinePix A340 Flash Unit Replacement: passo 6, immagine 1 di 1
    • Push both blue switches away from the holding device to unleach lcd ribbon.

    • Be careful when removing ribbon. If you damage it, you will need to replace it as well.

  7. FujiFilm FinePix A340 Flash Unit Replacement: passo 7, immagine 1 di 1
    • Carefully detach the ribbon from where it was connected by the blue pins.

  8. FujiFilm FinePix A340 Flash Unit Replacement: passo 8, immagine 1 di 1
    • Now that everything has been disconnected from the board, remove LCD screen.

  9. FujiFilm FinePix A340 Flash Unit Replacement, Motherboard: passo 9, immagine 1 di 1
    • Remove the two screws holding the circuit board down.

  10. FujiFilm FinePix A340 Flash Unit Replacement: passo 10, immagine 1 di 2 FujiFilm FinePix A340 Flash Unit Replacement: passo 10, immagine 2 di 2
    • Remove black sticky tape from circuit board and camera case.

  11. FujiFilm FinePix A340 Flash Unit Replacement: passo 11, immagine 1 di 2 FujiFilm FinePix A340 Flash Unit Replacement: passo 11, immagine 2 di 2
    • Gently pull the circuit board away from the front side of the camera.

    • Be careful when removing assembly as to not break any solder leads or damage lens assembly.

  12. FujiFilm FinePix A340 Flash Unit Replacement: passo 12, immagine 1 di 2 FujiFilm FinePix A340 Flash Unit Replacement: passo 12, immagine 2 di 2
    • Remove the logic board by pulling straight away from assembly.

  13. FujiFilm FinePix A340 Flash Unit Replacement, Flash Unit: passo 13, immagine 1 di 1
    • Locate the flash unit of the camera. It includes the camera's flash and a capacitor.

  14. FujiFilm FinePix A340 Flash Unit Replacement: passo 14, immagine 1 di 2 FujiFilm FinePix A340 Flash Unit Replacement: passo 14, immagine 2 di 2
    • Unsolder the flash unit at it's three points.

    • Be careful not to damage the circuit board or surrounding parts with the solder iron.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Un'altra persona ha completato questa guida.

Cody

Membro da: 04/18/10

47 Reputazione

4 Guide realizzate

Team

Cal Poly, Team 7-11, Maness Spring 2010 Membro di Cal Poly, Team 7-11, Maness Spring 2010

CPSU-MANESS-S10S7G11

3 Membri

4 Guide realizzate

0 Commenti

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 0

Ultimi 30 Giorni: 5

Tutti i Tempi: 3,892