In this guide we will replace the sensor located under the weighing surface of the scale. This guide should be used when the sensor is defective and needs to be replaced.

Parti

Nessuna parte specificata.

  1. Flip the device over and remove the battery cover.
    • Flip the device over and remove the battery cover.

  2. Remove the two screws (length: 7/16") located underneath the battery cover.  Use a Phillip's head number 1 screwdriver.
    • Remove the two screws (length: 7/16") located underneath the battery cover. Use a Phillip's head number 1 screwdriver.

  3. Once the screws are removed, lift up the metal weighing plate with your hands.  At this point in the process, the sensor will still be attached.
    • Once the screws are removed, lift up the metal weighing plate with your hands. At this point in the process, the sensor will still be attached.

  4. Kit di riparazione per Android

    A new screen or battery is one kit away.

    Acquista ora

    Kit di riparazione per Android

    A new screen or battery is one kit away.

    Acquista ora
  5. Using your hands or a plastic opening tool, peel back the metal plate from the plastic underneath.  This will expose the screws connecting the sensor to the plastic.
    • Using your hands or a plastic opening tool, peel back the metal plate from the plastic underneath. This will expose the screws connecting the sensor to the plastic.

  6. Using the same screwdriver as before, remove the two screws (length 3/8") on the plastic plate connected the sensor.
    • Using the same screwdriver as before, remove the two screws (length 3/8") on the plastic plate connected the sensor.

  7. With the sensor detached, use a plastic opening tool to peel away the glue holding the wires. With the sensor detached, use a plastic opening tool to peel away the glue holding the wires.
    • With the sensor detached, use a plastic opening tool to peel away the glue holding the wires.

  8. Remove the glue on the third side so that the wires are completely disconnected from the sensor.  You should now be able to replace the defective sensor with your new one. Remove the glue on the third side so that the wires are completely disconnected from the sensor.  You should now be able to replace the defective sensor with your new one.
    • Remove the glue on the third side so that the wires are completely disconnected from the sensor. You should now be able to replace the defective sensor with your new one.

Conclusione

To reassemble your device, follow these instructions in reverse order.

Altre 3 persone hanno completato questa guida.

Robert Muehler

Membro da: 03/09/2015

285 Reputazione

2 Guide realizzate

Team

USF Tampa, Team 1-2, Sullivan Fall 2015 Membro di USF Tampa, Team 1-2, Sullivan Fall 2015

USFT-SULLIVAN-F15S1G2

3 Membri

2 Guide realizzate

I'm sorry, I don't have a comment to add. Instead; I have a question to ask. Would a defective sensor be the reason my AWS-100 pocket weighing scales would continuously read full? I purchased them in September or October of 2017. They have not been dropped or managed roughly in any way. I've used them possibly 50- 60 times in this time span. I wipe them down before and after each use trying to make sure I get all of the residual particles cleaned off. I've been using a dry microfiber cloth mostly. On occasion I will dampen the cloth with a fine mist of water and use that. I always leave the lid opened for at least a hour to hour and a half on a clean, flat, dry surface ;before I return them to the box for storage. I make sure there isn't anything placed on top of them.

Can you help me? PLEASE!

TiddlieWink - Replica

Can anyone refer me as to where to buy a new sensor?

Brandy Lynn - Replica

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 2

Ultimi 7 Giorni: 13

Ultimi 30 Giorni: 49

Tutti i Tempi: 3,196