Introduzione

This guide will show the procedure for removing each segment of the pump rod. It can be used to replace the entire rod, or just to replace a single pump rod segment.

Strumenti

Nessun attrezzo richiesto.

Parti

Nessuna parte richiesta.

Assemble the required tools, including the Afridev tool and crescent wrenches.
  • Assemble the required tools, including the Afridev tool and crescent wrenches.

Aggiungi Commento

Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.
  • Perform a water test on the pump, by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.

Aggiungi Commento

  • Loosen the bolt on front of the face plate with the Afridev tool.

  • Remove the plate from the pump by lifting it straight up.

Aggiungi Commento

  • Insert the T-handle into the top cylinder of the exposed pump rod.

Aggiungi Commento

  • Loosen the 2 bolts on either side of handle.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Aggiungi Commento

  • Loosen the 2 bolts on either side of the head to remove the handle from the pump rod.

  • It is not necessary to remove the bolt at this time; however, take caution to not let the bolt fall out of the handle.

Aggiungi Commento

  • Lift the handle to a horizontal position.

Aggiungi Commento

  • While one person lifts up on the T-handle, remove the bolt and connection pieces.

Aggiungi Commento

  • Remove the bolt and connection pieces from the handle.

  • Set the bolt pieces in a sanitary place, such as a bucket, to prevent contamination.

Aggiungi Commento

  • Remove the handle from the pump.

  • Be sure to set the handle in a sanitary place to prevent contamination.

Aggiungi Commento

  • Grab firmly on the T-handle and lift the pump rod straight up.

  • Expose the first connection of the pump rod, and support the portion below the connection.

Aggiungi Commento

  • While holding the pump rod below the first connection tightly, lower the first portion of the rod to a horizontal position.

Aggiungi Commento

  • Unhook the first connection by pushing it out and down, then pulling it away from the rest of the rod.

Aggiungi Commento

  • Repeat steps 11-13 for the remaining sections of pump rod.

  • Be sure to set the pump rod segments above the ground to avoid contamination.

Aggiungi Commento

Conclusione

To reassemble your device, follow these instructions in reverse order.

Un'altra persona ha completato questa guida.

Jake Devincenzi

Membro da: 18/04/2011

105.074 Reputazione

112 Guide realizzate

Aggiungi Commento

Visualizza Statistiche:

Ultime 24 Ore: 0

Ultimi 7 Giorni: 0

Ultimi 30 Giorni: 1

Tutti i Tempi: 186